Abstract

ABSTRACT THE boundary integral equation method (BIEM) was developed in this study to analyze the performance of steady state potential type problems. The numerical implementation of BIEM was done for earth tube heat exchangers as an example. Based on the steady state heat conduction equation and a constant temperature boundary condition along the soil-tube interface, an equation for predicting the thermal performance for earth tube systems was developed. The earth tube variables studied included: tube diameter, soil temperature, and ambient air temperature. The location of tubes below the ground level significantly affected the heat exchanger thermal performance. Earth tube exchangers for heating greenhouses during winter months can be economical.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.