Abstract

Earth pressure data from the field instrumentation of a cast-in-place reinforced rectangular box culvert are presented in this paper. The instrumented culvert is a 2.60 m by 3.60 m double-cell reinforced cast-in-place rectangular box buried under 25.10 m of fill constructed using the induced trench installation (ITI) method. The average earth pressure measured across the roof was 0.42 times the overburden pressure, and an average of 0.52 times the overburden pressure was measured at mid-height of the culvert on the sidewalls. Base contact pressure under the rectangular box culvert was also measured, providing field-based data demonstrating increased base pressure resulting from downward drag forces developed along the sidewalls of the box culvert. An average increase of 25% from the measured vertical earth pressures on the roof plus the culvert dead load (DL) pressure was calculated at the culvert base. A model culvert was also tested in a geotechnical centrifuge to obtain data on earth pressures at the top, sides, and base of the culvert. The data from the centrifuge testing were compared with the prototype structure, and the centrifuge test results agreed closely with the measured field prototype pressures, in spite of the fact that full similitude was not attempted in centrifuge testing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.