Abstract
High-performance integrated circuits are now reaching the 100-plus watt regime, and power delivery and power grid signal integrity have become critical. Analyzing the performance of the power delivery system requires knowledge of the current drawn by the functional blocks that comprise a typical hierarchical design. However, current designs are of such complexity that it is difficult for a designer to determine what a realistic worst-case switching pattern for the various blocks would be in order to maximize noise at a specific location. This paper uses information about the power dissipation of a chip to derive an upper bound on the worst-case voltage drop at an early stage of design. An exact integer linear programming (ILP) method is first developed, followed by an effective heuristic to speed up the exact method. A circuit of 43 K nodes is analyzed within 70 s, and the worst-case scenarios found correlate well with the results from an ILP solver.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.