Abstract
Large-scale deep variable load of thermal power units will increase the hidden trouble of auxiliary equipment failure. Timely detection of minor faults and early warning are conducive to the safe operation of units. With the large-scale deep variable load of units, the operating conditions of auxiliary equipment also change in a large range, and the operating parameters fluctuate in a large range, which directly affects the accuracy of fault early warning algorithm based on operation data. In order to solve this problem, this paper uses a multivariate state estimation technique (MSET) algorithm for fault early warning. Firstly, the cluster method is used to divide the operating conditions of units, and process memory matrix is constructed under different operating conditions for modeling and calculation. The simulation results show that compared with the traditional method using one process memory matrix this method significantly improves the accuracy of fault early warning.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.