Abstract
Early warning or leading indicators are discussed for unexpected incidences in case of large-scale underground coal storage at a power plant. The experience is compared with above-ground stockpiles for which established procedures are available but where access for prevention and mitigation are much easier. It is suggested that while the explicit organization, procedures, and the general safety systems aim to provide the targeted levels of performance for the storage, representing new technology without much precedence elsewhere in the world, the extensive experience and tacit knowledge from above-ground open and closed storage systems can help to prepare for and to prevent unwanted incidents in the underground storage. This kind of experience has been also found useful for developing the leading or early warning indicators for underground storage. Examples are given on observed autoignition and freezing of coal in the storage silos, and on occupational hazards. Selection of the leading indicators needs to consider the specific features of the unique underground facility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Risk analysis : an official publication of the Society for Risk Analysis
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.