Abstract

Study ObjectiveTo evaluate the impact of the new donor heart allocation system implemented in the United States in October 2018 on development of early cardiac allograft vasculopathy (CAV). DesignRetrospective cohort study. ParticipantsAdult (≥ 18 years) heart transplant recipients registered in the United Network for Organ Sharing database between October 18, 2015 and October 17, 2018 (old system) and October 18, 2018 and May 31, 2020 (new system). Main Outcome MeasureIncidence of angiographic CAV at 1 year (accelerated CAV) in the overall transplant population and among the highest acuity subgroup—Status 1A (old) and Status 1 or 2 (new). We included recipient and donor demographic, cardiovascular, and transplant factors in multivariable logistic regression models to identify predictors of accelerated CAV. ResultsOf 10,375 transplant recipients, 6,660 (64%) and 3,715 (36%) were listed in the old and new allocation cohorts, respectively. The incidence of accelerated CAV was 521 (8%) in the old period compared with 272 (7%) in the new period (P = .36). Similar incidence rates were observed in the highest acuity subgroup—363 (8%) compared with 143 (7%), respectively (P = .13). In adjusted analyses of the high-acuity cohort, the new allocation system was not associated with a higher likelihood of accelerated CAV (odds ratio = 0.87, 95% confidence interval: 0.70-1.08, P = .20). ConclusionsThe new donor heart allocation system is not associated with development of accelerated angiographic CAV at 1 year, including among recipients requiring the most urgent transplants.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call