Abstract

It is shown that pre-crack and early stage fatigue damage can be characterized by a new sensor technology, the Meandering Winding Magnetometer (MWM™). This new technology consists of a conformable sensor, the MWM, and associated measurement grids that are model based. Measurements on type 304 stainless steel indicated that damage is readily detectable at 20% of life (N/NF = 0.2) and causes a 1.5% conductivity loss. Near failure the conductivity loss in the crack-free region was approximately 4%. In 2024 aluminum the onset of detectable fatigue damage was observed at approximately 50% of total life. For the probe geometry employed, the conductivity loss in the microcrack region just prior to failure was 7%; in the macrocrack region it reached 13%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.