Abstract
As part of power delivery network verification, one should check if the voltage fluctuations exceed some critical threshold. In this work, we consider the power and ground grids together and describe an early verification approach under the framework of current constraints where tight lower and upper bounds on worst-case voltage fluctuations are computed via linear programs. Experimental results indicate that the proposed technique results in errors in the range of a few mV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.