Abstract

Background and Objectives: Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboembolic events due to TAVR implantation, high incidence of coronary artery diseases (CAD) with the necessity of coronary intervention, and high rate of atrial fibrillation with the need of stroke prevention. We sought to evaluate the safety, efficiency, and clinical outcomes of early PPI following TAVR using the PlasmaBlade™ (Medtronic Inc., Minneapolis, MN, USA) pulsed electron avalanche knife (PEAK) for bleeding control in patients under DAPT or OAK. Materials and Methods: This retrospective single-center study included patients who underwent PPI after transfemoral TAVR (TF) at our center between December 2015 and May 2020. All PPI were performed using the PlasmaBlade™ Device. Results: The overall PPI rate was 14.1% (83 of 587 patients; 82.5 ± 4.6 years; 45.8% male). The PPI procedures were used to treat high-grade atrioventricular block (81.9%), severe sinus node dysfunction (13.3%), and alternating bundle branch block (4.8%). At the time of the procedure, 35 (42.2%) patients received DAPT, and 48 (57.8%) patients received OAK (50% with vitamin K antagonist (VKA) and 50% with novel oral anticoagulants (NOAK)). One device-pocket hematoma treated conservatively occurred in a patient (1.2%) receiving NOAK. Two re-operations were necessary in patients due to immediate lead dislocation (2.4%). Conclusions: The results of this study illustrate that the use of PlasmaBlade™ for PPI in patients after a TAVR who require antithrombotic treatment is feasible and might result into lower rates of severe bleeding complications compared to rates reported in the literature. Use of the PlasmaBlade device may be considered in this specific group of patients because of their high risk of bleeding.

Highlights

  • Aortic valve stenosis (AS) is the most frequent valvular disease in the elderly population

  • The present study aimed to evaluate the safety and efficiency using the PlasmaBladeTM for prevention of bleeding complications in transcatheter aortic valve replacement (TAVR) patients under Dual antiplatelet therapy (DAPT) or OAK-Therapy requiring early or delayed pacemaker implantation (PPI) (48 h after TAVR) to identify parameters leading to increased morbidity and prolonged hospitalization

  • TAVR-related PPI was defined as PPI at ≤30 days after the procedure

Read more

Summary

Introduction

Aortic valve stenosis (AS) is the most frequent valvular disease in the elderly population. Transcatheter aortic valve replacement (TAVR) is an effective treatment for severe symptomatic AS in high-risk patients [1], and its use has rapidly increased worldwide in recent years. Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboembolic events due to TAVR implantation, high incidence of coronary artery diseases (CAD) with the necessity of coronary intervention, and high rate of atrial fibrillation with the need of stroke prevention. Conclusions: The results of this study illustrate that the use of PlasmaBladeTM for PPI in patients after a TAVR who require antithrombotic treatment is feasible and might result into lower rates of severe bleeding complications compared to rates reported in the literature. Use of the PlasmaBlade device may be considered in this specific group of patients because of their high risk of bleeding

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.