Abstract

ObjectiveThe only commercially available thoracic branched endoprosthesis (TBE) for treatment of the aortic arch was released in 2022. Limited data outside of clinical trial results have been reported. This study describes the demographics, anatomic details, and outcomes for patients treated for zone 0 to 2 using TBEs outside of a clinical trial. MethodsAll patients treated using TBEs for zone 0 to 2 were included. Patients treated as part of the clinical trial for zone 0 to 1 (n = 6) were excluded. Patient demographics, comorbidities, anatomic and operative details, and outcomes were reported. Outcomes and survival were then compared between groups. ResultsOf 40 patients, six patients underwent repair of zone 0, three of zone 1, and 31 of zone 2. There were no differences in demographics, comorbidities, or operative details by zone of treatment; however, the frequency of genetic aortopathy differed (zone 0: 0%; zone 1: 67%; and zone 2: 6.4%; P < .01). Seventy-three percent of patients were treated for dissection vs 27% with isolated aneurysms. Of the patients, 2.5% were treated for rupture, 22% were treated for symptomatic aneurysms, and 75% were treated electively. Forty-eight percent of repairs included a proximal cuff, and 83% received distal extension. Technical success was achieved in 100% of patients. Mean fluoroscopy time was 18 minutes, and median fluoroscopy dose was 416 mGy. Sixty percent of patients had prior aortic ascending/arch repair. TBE was planned as part of a complete thoracoabdominal repair in 45% of patients. Thirty-day mortality was 2.5% overall, with a single death in a zone 0 patient that occurred at day 1 due to a myocardial infarction. There were no reinterventions within 30 days. All other outcomes were similar. The 30-day stroke rate was 5.0%. The strokes occurred at day 6 (zone 1) and day 15 (zone 2); however, both were due to occlusion of a prior proximal surgical bypass and unrelated to the TBE side branch or embolization. Specifically, both patients had occlusion of a branch of their prior zone 1 or zone 2 arch replacement. An endoleak occurred in 7.5% of patients at 30-day follow-up (type II: 5.0%; unknown: 2.5%). At a mean follow-up of 6.6 months, 100% of side branches were patent. ConclusionsRepair of the aortic arch including TBE can be performed electively and urgently with acceptable stroke and death rates. TBE provides a valuable tool for patients requiring complete repair of a thoracoabdominal aneurysm. Continued investigation is underway to assess long-term safety and efficacy outside of the clinical trial.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.