Abstract

To investigate the early effectiveness of the Ti-Robot assisted femoral neck system (FNS) in the treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures. A retrospective analysis was conducted on the clinical data of 41 elderly patients with Garden type Ⅱ and Ⅲ femoral neck fractures who were admitted between December 2019 and August 2022 and met the selection criteria. Among them, 21 cases were treated with Ti-Robot assisted FNS internal fixation (study group), and 20 cases were treated solely with FNS internal fixation (control group). There was no significant difference in baseline data, including gender, age, side, cause of injury, time from injury to surgery, fracture Garden classification, and fracture line classification, between the two groups ( P>0.05). Surgical effectiveness was evaluated based on parameters such as operation time (including incision time and total operation time), reduction level, number of dominant pin insertions, intraoperative fluoroscopy frequency, incision length, whether to extend the incision, need for assisted reduction, postoperative hospital stay, fracture healing time, incidence of osteonecrosis of the femoral head, postoperative visual analogue scale (VAS) score at 1 day, and Harris hip score at last follow-up. The study group showed significantly shorter incision time, fewer dominant pin insertions, fewer instances of extended incisions, fewer intraoperative fluoroscopy frequency, and smaller incisions than the control group ( P<0.05). There was no significant difference in total operation time, reduction level, and assisted reduction frequency between the two groups ( P>0.05). Both groups achieved primary wound healing postoperatively, with no complications such as incision leakage or skin infection. All patients were followed up 12-24 months with an average of 14.6 months. Fractures healed in both groups, with no significant difference in healing time ( P>0.05). There was no significant difference in postoperative hospital stay between the two groups ( P>0.05). The study group showed significantly better VAS score at 1 day after operation and Harris hip score at last follow-up when compared to the control group ( P<0.05). No complication such as internal fixation failure, fracture displacement, or hip joint varus occurred in both groups during the follow-up. Osteonecrosis of the femoral head occurred in 1 patient of the control group, while no was observed in the study group, and the difference in the incidence of osteonecrosis of the femoral head between the two groups was not significant ( P=0.488). Compared to sole FNS internal fixation treatment, Ti-Robot assisted FNS internal fixation for elderly Garden typeⅡ and Ⅲ femoral neck fractures can reduce incision time, achieve minimally invasive and accurate nail implantation, and decrease intraoperative fluoroscopy frequency, leading to improved postoperative hip joint function recovery.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call