Abstract

The early biological impact of short-term mechanical ventilation on healthy lungs is unknown. The authors aimed to characterize the immediate tidal volume (VT)-related changes on lung injury biomarkers in patients with healthy lungs and low risk of pulmonary complications. Twenty-eight healthy patients for knee replacement surgery were prospectively randomized to volume-controlled ventilation with VT 6 (VT6) or 10 (VT10) ml/kg predicted body weight. General anesthesia and other ventilatory parameters (positive end-expiratory pressure, 5 cm H2O, FIO2, 0.5, respiratory rate titrated for normocapnia) were managed similarly in the two groups. Exhaled breath condensate and blood samples were collected for nitrite, nitrate, tumor necrosis factor-α, interleukins-1β, -6, -8, -10, -11, neutrophil elastase, and Clara Cell protein 16 measurements, at the onset of ventilation and 60 min later. No significant differences in biomarkers were detected between the VT groups at any time. The coefficient of variation of exhaled breath condensate nitrite and nitrate decreased in the VT6 but increased in the VT10 group after 60-min ventilation. Sixty-minute ventilation significantly increased plasma neutrophil elastase levels in the VT6 (35.2 ± 30.4 vs. 56.4 ± 51.7 ng/ml, P = 0.008) and Clara Cell protein 16 levels in the VT10 group (16.4 ± 8.8 vs. 18.7 ± 9.5 ng/ml, P = 0.015). Exhaled breath condensate nitrite correlated with plateau pressure (r = 0.27, P = 0.042) and plasma neutrophil elastase (r = 0.44, P = 0.001). Plasma Clara Cell protein 16 correlated with compliance (r = 0.34, P = 0.014). No tidal volume-related changes were observed in the selected lung injury biomarkers of patients with healthy lungs after 60-min ventilation. Plasma neutrophil elastase and plasma Clara Cell protein 16 might indicate atelectrauma and lung distention, respectively.

Highlights

  • The early biological impact of short-term mechanical ventilation on healthy lungs is unknown

  • A significant increase in plasma levels of neutrophil elastase in the VT 6 (VT6) group and Clara cell protein 16 in the VT10 group were observed which may represent the effect of atelectrauma and increased alveolar distention, respectively recently developed risk scores for predicting ARDS15–19 or postoperative pulmonary complications[13,20] in their goal of early detection and prevention of lung inflammation

  • At the 0-min time point, as it was expected from the study design, the VT10 group had lower respiratory rate and greater exhaled VT, minute volume ventilation, peak and plateau airway pressures and compliance

Read more

Summary

Introduction

The early biological impact of short-term mechanical ventilation on healthy lungs is unknown. Exhaled breath condensate and blood samples were collected for nitrite, nitrate, tumor necrosis factor-α, interleukins-1β, -6, -8, -10, -11, neutrophil elastase, and Clara Cell protein 16 measurements, at the onset of ventilation and 60 min later. Sixty-minute ventilation significantly increased plasma neutrophil elastase levels in the VT6 (35.2 ± 30.4 vs 56.4 ± 51.7 ng/ ml, P = 0.008) and Clara Cell protein 16 levels in the VT10 group (16.4 ± 8.8 vs 18.7 ± 9.5 ng/ml, P = 0.015). Exhaled breath condensate nitrite correlated with plateau pressure (r = 0.27, P = 0.042) and plasma neutrophil elastase (r = 0.44, P = 0.001). Conclusions: No tidal volume-related changes were observed in the selected lung injury biomarkers of patients with healthy lungs after 60-min ventilation. Plasma neutrophil elastase and plasma Clara Cell protein 16 might indicate atelectrauma and lung distention, respectively. (­Anesthesiology 2014; 121:469-81)

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call