Abstract

Abstract Introduction Conduction disturbances (CD) after TAVI remains the most frequent complication of the procedure, frequently increasing the length of hospital stay. A lack of consensus exists regarding in-hospital management of CD post-TAVI. Purpose To evaluate if an early discharge (ED) protocol could be safely implemented in patients (pts) with CD post-TAVI. Methods Retrospective study of all pts submitted to TAVI between 2016 and 2018. Pts with prior permanent pacemaker (PP) and non-transfemoral approach were excluded. ECG data before, immediately after the procedure and at day 3 post-TAVI were collected, and continuous telemetry monitoring was recorded. We applied a recently proposed ED algorithm (adapted from Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement - JACC Scientific Expert Panel; JACC 2019; 74(8):1086–106) to identify which pts could have been candidates for ED. ED was defined as discharge in the first 72 hours (h) after the procedure. We evaluated if an ED strategy would have been safe at 1-year follow-up (FUP), as defined by the absence of need for PP, syncope and mortality. Results 242 pts were included, 44,8% males, mean age 80,4 years, mean Euroscore II 5,4 and the majority implanted a self-expandable prosthesis (64,1%). Mean hospital stay after TAVI was 7,7 days. The most frequent CD after TAVI were: new onset left bundle brunch block (36%) and high degree atrioventricular block (HAVB) (16,3%). During hospital stay 21,6% needed PP, mainly because of HAVB (mainly implanted in the first 72h). According to the proposed algorithm, 70,7% of our pts were ED-candidates. ED-candidates had lower prevalence of predilation (18,5% vs 36,8%, p=0,008) with no significant differences between type of prosthesis or baseline ECG. ED-candidates had smaller PR interval post-TAVI (184,5 vs 202,5 ms, p=0,044) and smaller PR and QRS at 72h (p<0,001 in both). At 1-year FUP, only 2,3% of ED-candidates needed a PP (vs 37,7% non-ED, p<0,001). It is noteworthy that in those ED-candidates who needed a PP during FUP, the percentage of ventricular pacing was less than 2% at 6 months. In the FUP period, 3,2% of ED candidates presented at the ER because of syncope, with no significant differences to non-ED pts. No differences between groups were found in 30-days and 1-year ER presentation because of syncope or all-cause mortality. Conclusions According to the proposed algorithm for ED in pts with CD post-TAVI, pts with specific ECG characteristics and without rhythm events during continuous telemetry monitoring can be early discharged with long-term safety. Funding Acknowledgement Type of funding source: None

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.