Abstract
Due to an increasing number of dementia patients, the development of a rapid and sensitive method for cognitive assessment is awaited. Here, we examined the usefulness of a novel and short (3 min) eye tracking device to evaluate the cognitive function of normal control (NC, n = 52), mild cognitive impairment (MCI, n = 52), and Alzheimer's disease (AD, n = 70) subjects. Eye tracking total score declined significantly in MCI (**p < 0.01 vs NC) and AD (**p < 0.01 vs NC, ##p < 0.01 vs MCI), and correlated well with the mini-mental state examination (MMSE) score (r = 0.57, *p < 0.05). Furthermore, the eye tracking test, especially memory and deductive reasoning tasks, effectively discriminated NC, MCI and AD. The present novel eye tracking test clearly discriminated cognitive functions among NC, MCI, and AD subjects, thereby providing an advantage for the early detection of MCI and AD in screening.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.