Abstract

BackgroundLeft ventricular (LV) dysfunction in patients with aortic valve stenosis (AVS) is seen in two scenarios: in neonates and in elderly patients. Neonatal AVS may present as a congestive cardiac failure (CCF), while older children rarely present with CCF if they have not been diagnosed early. Only a few reports of LV dysfunction with AVS have been described in the literature. However, there is a paucity of data regarding the safety and effectiveness of balloon aortic valvuloplasty (BAV) in children with AVS with LV dysfunction. Therefore, the aim of this study was to evaluate outcomes to establish the safety and effectiveness of BAV in children with AVS and LV dysfunction in improving LV function and survival.MethodsA total of 160 BAVs were performed from 2004 to 2017; of these, 41 (25.6%) patients had LV dysfunction. We reviewed these cases, and data were obtained on clinical features, echocardiographic parameters including LV ejection fraction (LVEF) and LV dimensions, LV posterior wall, interventricular septal thickness, pressure gradient across the valve, aortic valve morphology and annulus and aortic insufficiency (AI), and angiographic parameters such as aortic and LV pressures, AI and annulus size, and balloon size. Echocardiography was done before the procedure, one day after intervention, at three months, at six months, and on regular follow-up. Mortality during and after the procedure and at follow-up was reported.ResultsChildren who had undergone BAV for AVS and LV dysfunction within the age range of six to 192 months showed a significant reduction in peak-to-peak pressure gradient (PPG) from 73.5 ± 30 mmHg to 26.7 ± 6.7 mmHg and improvement in LVEF from 32.8 ± 11% to 54.3 ± 12.7% after 24 hours. Instantaneous gradient on echocardiography after three months showed PPG was 29.8 ± 7.7 mmHg and mean LVEF was 63 ± 8.6%. Mean LV end-diastolic pressure was 20.8 ± 4.7 mmHg and decreased to 13 ± 2.4 mmHg. Four patients died, all of whom had severe LV dysfunction - one died during the procedure and three died within six to 20 hours after successful BAV. On average follow-up of 6.4 ± 3.8 years, with a range of three months to 13 years, there was no mortality, pressure gradient increased to 40 ± 16.3 mmHg (range, 20 to 90 mmHg), and three had BAV after one, four, and six years, respectively. There was an increase in AI from mild to moderate in five patients, but they did not require any intervention. Four patients had aortic valve replacement (AVR) with two patients having an increase in pressure gradient and AI after eight and 13 years, respectively. One patient had AI (+3) after BAV had AVR after three years, and one patient who had a very thick and dysplastic aortic valve with LVEF of 20% and pulmonary hypertension (PH) had AVR after six months.ConclusionPatients with AVS who develop LV dysfunction deteriorate and die soon without treatment. Our data suggest that BAV in children with aortic stenosis and LV dysfunction is safe and effective in the normalization of LV function.

Highlights

  • How to cite this article Chand R, Shaikh A, Kumar N, et al (May 27, 2020) Early and Intermediate-Term Outcome of Balloon Aortic Valvuloplasty in Children With Aortic Stenosis and Left Ventricular Dysfunction at Tertiary Care Hospital

  • Data were obtained on clinical features, echocardiographic parameters including Left ventricular (LV) ejection fraction (LVEF) and LV dimensions, LV posterior wall, interventricular septal thickness, pressure gradient across the valve, aortic valve morphology and annulus and aortic insufficiency (AI), and angiographic parameters such as aortic and LV pressures, AI and annulus size, and balloon size

  • Children who had undergone balloon aortic valvuloplasty (BAV) for aortic valve stenosis (AVS) and LV dysfunction within the age range of six to 192 months showed a significant reduction in peak-to-peak pressure gradient (PPG) from 73.5 ± 30 mmHg to 26.7 ± 6.7 mmHg and improvement in LVEF from 32.8 ± 11% to 54.3 ± 12.7% after 24 hours

Read more

Summary

Introduction

How to cite this article Chand R, Shaikh A, Kumar N, et al (May 27, 2020) Early and Intermediate-Term Outcome of Balloon Aortic Valvuloplasty in Children With Aortic Stenosis and Left Ventricular Dysfunction at Tertiary Care Hospital. If an obstruction is not relieved early, some patients develop systolic dysfunction, which may either be due to an afterload mismatch or decrease in contractile function of the myocardium [5,6] This is secondary to myocardial ischemia resulting from the combination of limited cardiac output, reduced coronary perfusion, and increased myocardial oxygen consumption leading to fibrosis in areas of the myocardium damaged by ischemia. The aim of this study was to evaluate the early and intermediate outcomes to establish the safety and effectiveness of BAV in children with aortic stenosis and LV dysfunction in improving LV function and survival. Left ventricular (LV) dysfunction in patients with aortic valve stenosis (AVS) is seen in two scenarios: in neonates and in elderly patients. The aim of this study was to evaluate outcomes to establish the safety and effectiveness of BAV in children with AVS and LV dysfunction in improving LV function and survival

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.