Abstract

Lean blowout (LBO) of a partially premixed swirl flame is studied using chemiluminescence imaging and simultaneous stereo-PIV and OH-PLIF measurements at repetition rates up to 5 kHz. The flame, which is operated with methane and air in a gas turbine model combustor at atmospheric pressure, features a pronounced precessing vortex core (PVC) at the inner shear layer. In the first part of the study, the stabilization mechanism of the flame close to LBO is investigated. The fields of velocity and OH show that near LBO there are essentially two regions where reaction takes place, namely the helical zone along the PVC and the flame root around the lower stagnation point. The zone along the PVC is favorable to the flame due to low strain rates in the vortex center and accelerated mixing of burned and fresh gas. The flame root, which is located close to the nozzle exit, is characterized by an opposed flow of hot burned gas and relatively fuel-rich fresh gas. Due to the presence of high strain rates, the flame root is inherently unstable near LBO, featuring frequent extinction and reignition. The blowout process, discussed in the second part of the study, starts when the extinction of the flame root persists over a critical length of time. Subsequently, the reaction in the helical zone can no longer be sustained and the flame finally blows out. The results highlight the crucial role of the flame root, and suggest that well-aimed modifications of flow field or mixture fraction in this region might shift the LBO limit to leaner conditions.