Abstract
A computational-experimental method for predicting and estimating the dynamical error in measuring the coolant temperature in VVER transient regimes is examined. The method is based on thermal probing of a thermocouple by passing an electric current pulse through the thermocouple wires and detecting and analyzing the transient characteristic using a special algorithm. The special features of the transient characteristics are investigated and an example of estimating the error is presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.