Abstract
W-beam systems utilise end-terminal anchorages to develop tension upstream and downstream of an impact event. However, the capacities of the anchorage components under impact loading are not well known. One such W-beam end-anchorage system, the Midwest guardrail system (MGS) trailing-end anchorage, was evaluated using three dynamic component tests – a soil foundation tube pull test, a breakaway cable terminal (BCT) post splitting test, and an MGS end-anchorage system pull test. The peak load recorded during a soil foundation tube test was 193 kN at 56 mm deflection, as measured at the ground line. BCT posts split at loads of 17.8 and 32.9 kN. The end-anchorage tensile capacity was 156 kN, dissipating 64.7 kJ. Results from the component tests were also used to create and validate nonlinear finite element models of the components in order to be used for future design and analysis of end anchorages.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.