Abstract
Based on the conservation equations of mass, energy, and momentum, the mathematical model of once-through steam generator (OTSG) with concentric annuli tube is developed by moving boundary. The heat transfer section of OTSG is divided into three regions: subcooled, nucleate boiling and superheated regions. An effective heat transfer length concept is used in superheated region. The stable and dynamic simulation equations are solved by Gear method. The stable results are validated by experimental data and the transient results are validated through code to code comparison using RELAP5 code as the basis. The results show that the developed model and code are accurate, effective and can be used to simulate the steam generator dynamics in real time.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.