Abstract

In this study, we aimed to determine the optimum operating conditions for the production of ethyl acetate (EtAc) through the esterification of ethanol (EtOH) with acetic acid (HAc) in a reactive distillation (RD) column. For this, the designed column was simulated for the production of EtAc. HAc flow rate, EtOH flow rate, HAc feed stage, EtOH feed stage, reflux ratio, and reactive feed temperatures were changed and the effects of these parameters on EtAc production were observed. Central Composite Design was employed to define the optimum operating conditions for the RD column. The determination coefficient R2 was equal to 0.9197 suggesting a good relationship between the predicted and simulated responses. Adjusted R2 and predicted R2 values obtained from the program were 0.8823 and 0.7956, respectively. The optimal conditions for the EtAc production response were HAc flow rate of 120.00 kmol/h, EtOH flow rate of 150.00 kmol/h, HAc feed stage 6, EtOH feed stage 14, reflux ratio 2.2, and feed temperature 70.28 °C, which were designated by the maximum desirability function.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.