Abstract

Reinforced concrete panels were tested explosion for reinforced concrete slab in the dynamic response under blast loading. Dimensions of 1300mm×1300mm×50mm plates under different reinforcement ratio were designed. Explosion test was carried out for three different batches of reinforcement ratio reinforced concrete slab in the explosion simulator. The load was calculated using empirical formulas. Blast loading time curve was obtained by the explosion test and the correctness of the numerical simulation method was verified. The results indicate that reinforced concrete slab under blast loading is different from static damage destruction. Diagonal cracks appear on plat under the blast loading destroyed. When the peak load is large, a large square cracks plate was appeared in the middle of the plate and accompanied diagonal cracks. When the peak load is small, diagonal cracks develop fully, square cracks were smaller.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.