Abstract

Abstract The paper presents selected results of work at the Air Force Institute of Technology (AFIT) in the concerning modeling the dynamic properties of fire detectors used in aviation fire protection systems. In order to determine the conditions of false fire signals, the simulation models of thermoelectric fire detectors have been developed. Simulation models were tested in Matlab-Simulink computational packages for various methods of heating and cooling the sensors (among others, changes in ambient air temperature of the sensor, caused by the EWU exhaust gas diffusers were simulated – these diffusers are used to distribute flue gases from helicopter engines).