Abstract

Given that automobile crashes are the largest single cause of death for pregnant females, scientists are developing advanced computer models of pregnant occupants. The purpose of this study is to quantify the dynamic material properties of the human uterus in order to increase the biofidelity of these models. A total of 19 dynamic tension tests were performed on pregnant human uterus tissues taken from six separate donors. The tissues were collected during full term Cesarean style deliveries and tested within 36h of surgery. The tissues were processed into uniform coupon sections and tested at 1.5strains/s using linear motors. Local stress and strain were determined from load data and optical markers using high speed video. The experiments resulted in a non-linear stress versus strain curves with an overall average peak failure true strain of 0.32±0.112 and a corresponding peak failure true stress of 656.3±483.9kPa. These are the first data available for the dynamic response of pregnant human uterus tissues, and it is anticipated they will increase the accuracy of future pregnant female computational models.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.