Abstract

The theoretical and experimental investigation of a cable-stayed bridge after major repair is described in this paper. Strengthening mainly involved the suspension system (originally with prestressed concrete stays) which was retrofitted by means of external tendons. Full-scale tests were conducted to measure the dynamic response of the repaired system; the experimental program included both traffic-induced and free vibration measurements. A total of 16 vertical frequencies and mode shapes were identified in the frequency range of 0–10 Hz. In the theoretical study, vibration modes involving deck, towers and cables were determined by using finite element models which accounted for the strengthening effects. Two- and three-dimensional models were used so that the importance of three-dimensional modes was estimated as well. The experimental results were compared to natural frequencies and mode shapes computed using theoretical models. For most modes the measured and predicted modal parameters compare well, especially for the vertical modes involving in-phase motion of the stays. © 1997 by John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call