This letter presents a dynamic hysteresis current control algorithm for a three-phase four-leg voltage-source inverter (VSI) topology. In order to improve the performance and life of the power switches of VSI, we require an optimized control technique that reduces its switching frequency. Proposed hysteresis current control method is a generalized control method that minimizes switching operations to compensate nonlinear load under both balanced and unbalanced supply voltages. It is shown that this control scheme is able to reduce the switching frequency by more than 50% compared to conventional hysteresis current control method and retain the quality of load compensation. The effectiveness of the proposed control scheme is illustrated through simulations using Power Systems Computer-Aided Design (PSCAD) 4.2.1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.