Abstract
This study shows the effect of dynamic flow on the degradation behaviour and mechanical integrity of porous magnesium. A test rig that mimics the environment surrounding a cancellous bone was developed and a dynamic immersion test was performed to assess the degradation rate of the material for bone scaffold application. Three different percentages of porous magnesium (30%, 41%, and 55%) were immersed in simulated body fluid. The results show that mass loss and mechanical integrity of the specimens deteriorated linearly with an increase in porosity and degradation time, correlating to a drop of 41% and 89%, respectively, within 3days.
Paper version not known (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.