Single-ended log-domain filters must operate class A: the amplitude of any symmetric signal must be less than the bias current. Even so, internal dynamic current requirements can be much higher than the bias currents. Worst-case peak current demands are related to the modulation index by simple expressions that allow transistor geometries to be optimized for specified signal levels. Some circuit topologies are shown to be better able to supply large internal currents than others.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.