Abstract

Microfluidic paper-based analytical devices (μPADs) rely on capillary flow to achieve filling, mixing and delivery of liquids. We investigate the use of electroosmotic (EO) pumping as a mechanism for dynamic control of capillary flow in paper-based devices. The applied voltage can accelerate or decelerate the baseline capillary-driven velocity, as well as be used to create a tunable valve that reversibly switches the flow on and off in an electrically controlled manner. The method relies on simple fabrication and allows repeated actuation, providing a high degree of flexibility for automation of liquid delivery. We adapt the Lucas-Washburn model to account for EO pumping and provide an experimentally validated analytical model for the distance penetrated by the liquid as a function of time and the applied voltage. We show that the EO-pump can reduce filling time by 6.5-fold for channels spanning several cm in length, relative to capillary filling alone. We demonstrate the utilization of the EO-pump for a tunable and dynamic flow control that accelerates, decelerates and stops the flow on demand. Finally, we present the use of the EO-pump for fluid flow sequencing on a paper-based device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.