Abstract

The incremental value of dynamic contrast-enhanced (DCE) imaging in localizing radiorecurrent prostate cancer is uncertain. To assess the added-value of DCE imaging to the combination T2 -weighted imaging (T2 W)+diffusion-weighted imaging (DWI) in detecting locally radiorecurrent prostate cancer (PCa), by radiologists with different levels of experience. Analytic retrospective study. In all, 52 men with biological suspected PCa recurrence after radiotherapy were retrospectively included. All men underwent prostatic MRI (1.5T or 3T), including T2 W, DWI, and DCE imagings, before biopsies. Two junior (6 months' experience) and two senior readers (more than 3 years' experience) independently assigned a Likert score for each prostatic sextant on T2 W+DW+DCE imagings, then on T2 W+DW imagings, 4 weeks later. The reference standard was prostatic biopsies. For two levels of positivity of Likert score, 3/5 and 4/5, sensitivity, specificity, area under the receiver operating curve (AUC), and interreader agreement were compared. T2 W+DWI+DCE and T2 W+DWI imaging had similar AUC at lobe and sextant level (0.853-0.946 vs. 0.819-0.955, P from 0.071-0.534). Using a Likert score ≥4/5, T2 W+DWI+DCE significantly improved the sensitivity for junior readers at the patient, lobe, and sextant level (40-80% vs. 22-66%, P < 0.0001-0.041). Sensitivity was not significantly modified with DCE imaging for senior readers (54-95% vs. 50-91%, P from 0.074-1). Specificity was not modified for all readers (50-100% vs. 50%-100%, P from 0.134-1). DCE imaging improved interreader agreement for a Likert score ≥4/5 (kappa from 0.6-0.73 vs. 0.38-0.73). The addition of DCE imaging did not significantly improve accuracy in recurrent PCa detection after radiotherapy, whatever the level of experience of the readers. However, the addition of DCE imaging slightly improved the sensitivity for less-experienced readers and increased their diagnostic confidence. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1012-1023.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.