Abstract The present study was conducted to determine the dynamic bending strength of the human forearm. A total of 30 human cadaver forearm specimens were tested using a three-point bending method to failure at 3.3 to 7.6 m/s speeds. Results indicated significantly (p < 0.01) greater mean failure moment for males (113 ± 39 Nm) compared to females (66 ± 25 Nm). The mean failure bending moment for all specimens was 94 Nm. The smaller sized occupant with lower bone mineral however, has one-half of this strength (approximately 45 Nm). The failure moment of the human forearm was found to be most highly correlated to bone mineral density and forearm weight. The present investigation offers quantitative information regarding strength of the human forearm useful for design of injury-mitigating devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.