Abstract

The paper presents a study on the seismic assessment of a 21-story building having an asymmetrical plan. The study applies the approach using in-situ measurements to assess the building's seismic performance. According to preliminary observations on site, the soil may have a significant influence on the building's behaviour. That is why it is important to isolate the behaviour of the building from the soil effect (fixed-base structure). First, in-situ dynamic measurements are conducted to identify dynamic characteristics of the building. The Frequency Domain Decomposition (FDD) method is used to determine the vibration modes of the building in three dimensions (3D). First three vibration modes with close frequencies and unusual mode shapes were identified, which shows the relevance of the used method in the case of buildings having complex behaviour. Second, the relevance of the applied approach was checked by using 3D Finite Element (FE) modelling, in both cases: fixed-base structure and soil + structure system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.