Abstract
The introduction of hybrid MR-PET scanners offers new perspectives to better correlate MR and PET data with respect to time and space domain. In case of brain tumor patients, dynamic susceptibility contrast (DSC)-MRI is often used to measure perfusion levels of brain, while dynamic [18F]-fluoro-ethyl-tyrosine (FET)-PET provides additional functional information. The dynamic analysis of data is becoming more relevant, rather than static analysis, and with this the extraction of parametric images. In this context, the aim of this work is to compare dynamic MR-PET data based on different features. A FET-PET scan was carried out on the 3T-MR-BrainPET [1] on each patient. Data was acquired for 60 min after injection in list-mode and reconstructed using OSEM3D software (4 subsets, 32 iterations). All MRI sequences were acquired simultaneous to the PET measurement. In this work, MPRAGE and DSC-MRI based on an EPI sequence images are used. For the dynamic analysis, data was co-registered and the same parameters were extracted, with Matlab, from MR-PET data to produce peak, time to peak (TTP), area under the curve (AUC) and wash-in parametric images. Results from 3 of the analyzed datasets from patients with brain tumors are presented on Figure Figure1.1. MPRAGE, DSC-MRI EPI sequence and FET-PET images and the extracted parametric images are shown. Figure 1 Analyzed datasets (i, ii and iii). MRI images (a) MPRAGE (post contrast), (b) DSC-MRI EPI, and the corresponding extracted parametric images: (c) peak and (d) AUC. (e) FET-PET image (summed image of 20-40 min p.i., previously filtered with a 2 mm Gaussian ... In FET-PET parametric images an uptake area can be identified in the region of morphological changes in anatomical MR. The parametric images provide extra information in addition to the summed FET-PET images. The time curves obtained from a gray-matter region defined on MPRAGE are presented on Figure Figure22. Figure 2 MRI and PET contrast time curves. The FET-PET data was truncated (the total acquisition time was 3600 s) in order to merge the two curves in one graph. The MRI and PET contrast time curves were normalized to the maximum to be able to compare the shape ... The extracted parametric images from dynamic MR-PET showed good spatial and temporal agreement (Figure (Figure1).1). These results suggest that dynamic MR-PET may have extra information about biology and that the combination of simultaneous acquisition and analysis may be beneficial.
Highlights
The introduction of hybrid MR-PET scanners offers new perspectives to better correlate MR and PET data with respect to time and space domain
MPRAGE and dynamic susceptibility contrast (DSC)-MRI based on an EPI sequence images are used
Results from 3 of the analyzed datasets from patients with brain tumors are presented on Figure 1
Summary
The introduction of hybrid MR-PET scanners offers new perspectives to better correlate MR and PET data with respect to time and space domain. The dynamic analysis of data is becoming more relevant, rather than static analysis, and with this the extraction of parametric images. The aim of this work is to compare dynamic MR-PET data based on different features. A FET-PET scan was carried out on the 3T-MR-BrainPET [1] on each patient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.