Abstract

In the present paper, the earlier developed model for wall window has been modified for rooftop window. The model has been validated for dynamic behavior by considering the hourly measured both direct and diffuse components of the sunlight and skylight under clear sky conditions. It can be used to predict the Daylight Illuminance Ratio (DIR) and daylight at a given point in living space. The annual energy saving from rooftop window has been estimated for different climatic locations in India. It has been observed that highest DIR was always along the line normal to the rooftop window and decreases as we go away from the normal line in all directions. It was found that, for increasing aperture to floor area ratio, the energy saving potential increases. The minimum annual energy saving was found to be 65.74kWh/m2 for Srinagar whereas the maximum was 77.10kWh/m2 for Bengaluru. The monthly average value of model exponent (p) has been computed as 1.25. Hence, the present model can be used to design building for optimum daylighting at a given point inside living space.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.