Abstract

The proposed 2005 edition of the National Building Code of Canada specifies dynamic analysis as the preferred method for computing seismic design forces and deflections, while maintaining the equivalent static force method for areas of low seismicity and for buildings with certain height limitations. Dynamic analysis procedures are categorized as either linear (elastic) dynamic analysis, consisting of the elastic modal response spectrum method or the numerical integration linear time history method, or nonlinear (inelastic) response history analysis. While both linear and nonlinear analyses require careful analytical modelling, the latter requires additional considerations for proper simulation of hysteretic response and necessitates a special study that involves detailed review of design and supporting analyses by an independent team of engineers. The paper provides an overview of dynamic analysis procedures for use in seismic design, with discussions on mathematical modelling of structures, structural elements, and hysteretic response. A discussion of the determination of structural period to be used in association with the equivalent static force method is presented.Key words: dynamic analysis, earthquake engineering, elastic analysis, fundamental period, hysteretic modelling, inelastic analysis, National Building Code of Canada, seismic design, structural analysis, structural design.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call