Abstract

Characteristics of the polyvinyl chloride (PVC) films containing 0.11 wt% of malachite green oxalate or 6GX-setoglausine and about 100 μm in thickness were studied for use as routine dosimeters in radiation processing. These films show basically color bleaching under irradiation with 60Co γ-rays in a dose range of 5–50 kGy. The sensitivity of the dosimeters and the linearity of dose-response curves are improved by adding 2.5% of chloral hydrate [CCl 3CH(OH) 2] and 0.15% hydroquinone [HOC 6H 4OH]. These additions extend the minimum dose limit to 1 kGy covering dosimetry requirements of the quality assurance in radiation processing of food and healthcare products. The dose responses of both dyed PVC films at irradiation temperatures from 20°C to 35°C are constant relative to those at 25°C, and the temperature coefficients for irradiation temperatures from 35°C to 55°C were estimated to be (0.43±0.01)%/°C. The dosimeter characteristics are stable within 1% at 25°C before and 60 days after the end of irradiation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.