Abstract

This paper presents a division-summation (D-Σ) digital control for a three-phase transformerless bi-directional photovoltaic inverter with wide inductance variation, which can eliminate the leakage ground currents due to panel parasitic capacitance. The bi-directional inverter fulfilling grid connection and rectification with power factor correction has been implemented in the laboratory. The proposed D-Σ approach summarizes the inductor-current variations over one switching cycle to derive control laws directly, which can overcome limitations of d-q transformation. With the digital control, the inverter can deal with wide inductance variation, reducing core size significantly. In the design and implementation, the inductances corresponding to various inductor currents are measured and tabulated into a single-chip microcontroller for tuning loop gain cycle by cycle, ensuring stable operation. Simulated and Measured results from a 10 kVA 3φ bi-directional inverter are presented to confirm the feasibility of the discussed control approaches.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.