Abstract
In this study, the dependence of the flammable concentration on particle size is investigated for Phase Change Material (PCM) and Encapsulated Phase Change Material (EPCM) particles using a novel continuous particle dispersion apparatus into which a propane flame is introduced creating a test akin to the flash-point test for liquids. The results show that the threshold concentration is a strong function of particle size. For tested particles with size ranging from 290 μm to 750 μm, the threshold concentration is above the predictions based on an instantaneous heat transfer limit, and is approximately linear with the particle size, following a heat transfer limited ignition model. For sizes above ≈1 mm, the particles behave like the bulk material, and ignition is not observed for the concentrations tested. The results obtained here are important for the safe construction, handling, and operation of systems using PCM and other particles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Loss Prevention in the Process Industries
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.