Abstract

Fast charging of lithium-ion batteries is often related to accelerated cell degradation due to lithium-plating on the negative electrode. In this contribution, an advanced electrode equivalent circuit model is used in order to simulate fast-charging strategies without lithium-plating. A novel parameterization approach based on 3-electrode cell measurements is developed, which enables precise simulation fidelity. An optimized fast-charging strategy without evoking lithium-plating was simulated that lasted about 29 min for a 0–80% state of charge. This variable current strategy was compared in experiments to a conventional constant-current–constant-voltage fast-charging strategy that lasted 20 min. The experiments showed that the optimized strategy prevented lithium-plating and led to a 2% capacity fade every 100 fast-charging cycles. In contrast, the conventional strategy led to lithium-plating, about 20% capacity fade after 100 fast-charging cycles and the fast-charging duration extended from 20 min to over 30 min due to increased cell resistances. The duration of the optimized fast charging was constant at 29 min, even after 300 cycles. The developed methods are suitable to be applied for any given lithium-ion battery configuration in order to determine the maximum fast-charging capability while ensuring safe and durable cycling conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call