Abstract

Forschungszentrum Jülich has demonstrated SOFC stacks and systems ranging from 50 W to 20 kW. Previous studies have shown the reproducible stable long-term performance of the F10-design short stacks developed in Forschungszentrum Jülich. Within this work, a 2.5 kW F20-stack consisting of eighteen cells was assembled, and tested at a furnace temperature of 700 °C mainly with the simulated reformate gas, which corresponds to 10% pre-reforming of liquefied natural gas (LNG). The current density and fuel utilization were mostly kept at 0.5 A cm−2 and 70%, respectively. The purpose was to investigate the behavior of the stack in the kW-range for at least 5000 h with internal reforming of LNG or methane at a fuel utilization of at least 60%. A voltage degradation rate of around 0.3%/1000 h was obtained during the operation with pre-reformed LNG. The stack performance under normal working conditions and an unplanned redox cycle, as well as the results from post mortem analysis are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.