Abstract

Clamped joints of wood frame buildings are a traditional way in Norway to attain airtight joints for the air and vapour barrier. There are numerous defects registered in the SINTEF Building Defects Archive related to air leakage through the vapour barrier, on one hand, and stricter requirements for reduced energy consumption, on the other hand, question today’s efficacy of these type of joints. This study investigates the durability of clamped joints by studying how the airtightness is affected by several drying and wetting cycles. Experimental work is carried out to measure air leakage rates, which in turn, are used to evaluate their impact on the airtightness of two different constructions by numerical estimations. Results show that the air leakage rates are increased significantly due to transient climatic conditions. Clamped joints may no longer provide airtight building envelopes given the stricter requirements for energy consumption and implications of climate change. A more promising and robust alternative is the use of self-adhesive tapes.