Abstract

At Waseda University, we have been studying for high quality electron beam generation using 1.6 cell Cesium Telluride (Cs-Te) photocathode rf-gun. We use photocathode as the electron source, which can generate high-quality electron beam such as low emittance, and short bunch. The performance of photocathode is evaluated mainly in terms of quantum efficiency (Q.E.) and lifetime. Cs-Te photocathode is known for high Q.E. about 10% with UV light and relatively longer lifetime among semiconductor photocathodes. Since it is a hard environment for photocathode inside the gun, it is necessary to replace the photocathode every several months. In other words, in order to achieve long-term operation of rf-gun, it is necessary to establish highly durable photocathode recipe. In this report, we report the evaluation results of Cs-Te photocathode by co-evaporation, CsBr coated photocathode performance in an rf-gun and future prospects.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.