Abstract
We have studied differences in reperfusion between the pancreas and the duodenum after 6 hr of cold storage in a porcine whole-organ pancreaticoduodenal allograft transplantation model. Two different flush-out and storage solutions, Perfadex and EuroCollins, were compared. Graft duodenal mucosal pH (pHi) was measured as an indicator of duodenal mucosal reperfusion. Pancreatic reperfusion was estimated indirectly using a ratio between the release of immunoreactive cationic trypsin (irCT) to serum 10 and 60 min following reperfusion. Twelve pigs (Perfadex n = 6, EuroCollins n = 6) were transplanted and all showed preserved endocrine and exocrine function postoperatively. Our data support the concept that reperfusion of a pancreaticoduodenal graft can be estimated using duodenal pHi and that the ratio of irCT at 10 and 60 min gives an indirect estimate of pancreatic reperfusion. The results also show that grafts stored in EuroCollins reperfuse more slowly than grafts stored in Perfadex.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.