Abstract

A new overall structural flexibility, referred to as “system flexibility,” is defined in this paper for building frames composed of material with an arbitrary, stable, nonlinear, elastic stress‐strain relation which are to be designed to support a set of prescribed lateral loads. The necessary and sufficient conditions for global optimality, and the closed‐form optimum design formula, are derived for the problem of optimum design of a building frame composed of nonlinear elastic beams and linear elastic columns for specified system flexibility. It is shown that, if the cost factors in the optimality conditions are reinterpreted as control parameters for maximum member‐end strains, then the closed‐form optimal design formula derived here can be utilized as a set of practically useful design formulas for ductility design of a building frame consisting of yielding beams (weak beams) and linear elastic columns. It is demonstrated further through a series of time history analyses that this static ductility des...