Abstract
We evaluated the results of sequential SPECT dual-isotope imaging with Tl-201 and Tc-99m MIBI in 24 patients. all of whom also had coronary angiography within the past one month. Coronary angiography showed that 12 patients had no CAD, 4 patients had one-vessel CAD, 7 patients had two-vessel CAD and 1 patient had three-vessel CAD. Serial studies of resting Tl-201 and dipyridamole stress Tc-99m MIBI were completed within 2 hours. When more than 50% of coronary artery narrowing was considered significant, the overall sensitivity and specificity of CAD detection were 91.7%. The sensitivity of CAD detection in patients with one-vessel and multi-vessel diseases was 75% and 100%. respectively. Therefore, sequential dual-isotope SPECT demonstrated high sensitivity and specificity for CAD detection. In conclusion, sequential dual-isotope imaging is feasible and can be completed in a short time and may therefore enhance laboratory throughput and patient convenience.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.