Abstract

We report a dual-readout, AuNP-based sandwich immunoassay for the device-free colorimetric and sensitive scanometric detection of disease biomarkers. An AuNP-antibody conjugate serves as a signal transduction and amplification agent by promoting the reduction and deposition of either platinum or gold onto its surface, generating corresponding colorimetric or light scattering (scanometric) signals, respectively. We apply the Pt-based colorimetric readout of this assay to the discovery of a novel monoclonal antibody (mAb) sandwich pair for the detection of an anthrax protective antigen (PA83). The identified antibody pair detects PA83 down to 1 nM in phosphate-buffered saline and 5 nM in human serum, which are physiologically relevant concentrations. Reducing gold rather than platinum onto the mAb-AuNP sandwich enables scanometric detection of subpicomolar PA83 concentrations, over 3 orders of magnitude more sensitive than the colorimetric readout.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.