Abstract

The sustained apnea for epicardial access with right ventriculography technique (SAFER epicardial approach) has been previously shown to be effective and safe (1). However, it requires a brief period of unprotected needle dwell time within the pericardium while the operator switches the contrast syringe for a guidewire. This transition period, though brief, raises concerns regarding the potential risk of inadvertent perforation of the right ventricular (RV) wall given the systolic-diastolic excursion of the heart and/or the possibility of losing epicardial access. In an effort to limit the unprotected needle dwell time in the pericardium, we describe the dual operator modified SAFER epicardial approach.