Abstract

To improve the efficiency of full-bridge converter operating under wide input voltage conditions, this Letter proposes a dual mode modulation method. The full-bridge converter is controlled by phase-shifted mode at low input voltage and asymmetric pulse width modulation mode at high input voltage. The proposed method can reduce power loss, voltage stress of rectifier and output filter requirement. A 500-W full bridge converter with a 160 to 400 V input voltage range is built to confirm the validity of the proposed dual mode method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.