Abstract

In this study, a dual-interrogation (DI) method was used to suppress the light shift in the Rb 778 nm 5S1/2→5D5/2 two-photon transition optical frequency standard (2hν-OFS). The approach used an auxiliary system to calibrate the light shift of the primary system in real time to mitigate the absolute light shift and suppress the sensitivity of the system to the light power. Results show that after using the DI method, the absolute light shift and light-power sensitivity of the system were reduced by a factor of 10. The proposed method will improve the accuracy of the Rb 778 nm 2hν-OFS and increase the mid- and long-term stability. The method can also be applied to other vapor-cell atomic frequency standards that experience light shifts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.