Abstract

The aim of this study was to assess the value of dual-energy chest radiography obtained using a cesium iodide flat-panel detector in addition to standard posteroanterior chest radiography for the detection of calcified chest abnormalities. The study included 20 patients with a total of 37 calcified chest lesions (16 pulmonary nodules, 17 mediastinal calcifications, and four pleural calcifications) as confirmed on CT. Twenty-eight locations in the chests of the same patients who were free of lesions were used as negative controls. Four radiologists reviewed posteroanterior chest radiographs in a blinded manner alone and in conjunction with dual-energy soft-tissue and bone images. We calculated sensitivity, specificity, the negative predictive value (NPV), and the positive predictive value (PPV) for lesion prediction. The Wilcoxon's and the Brunner and Langer's tests were performed for statistical analysis. For posteroanterior chest radiography, sensitivity was 36%, the PPV was 64%, and the NPV was 47%. When dual-energy images were added, sensitivity increased significantly to 66% (p < 0.05), the PPV to 76%, and the NPV to 62%. The specificity remained constant at 73%. Brunner and Langer's test revealed a highly significant difference between posteroanterior chest radiography and dual-energy imaging in the detection of calcified chest abnormalities (p < 0.01). Dual-energy images added to standard posteroanterior chest radiographs significantly improve the detection of calcified chest lesions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call