Abstract

ObjectiveTo evaluate the safety and effectiveness of a 20-mm diameter dual-design expandable colorectal stent for malignant colorectal obstruction.Materials and MethodsThe study series included 34 patients with malignant colorectal obstruction who underwent implantation of a 20-mm dual-design expandable colorectal stent in our department between March 2009 and June 2010. The 20-mm dual-design expandable colorectal stent was placed by using a 3.8-mm delivery system that had 28-mm diameter proximal and distal ends. Among the 34 patients, stent placement for palliation was performed in 20 patients, while stent placement for bridge to surgery was performed in 14 patients.ResultsA 97% (33 of 34) success rate was achieved for the stent placement. The perforation rate in the bridge to surgery group was 7% (1 of 14), compared to 0% (0 of 19) in palliative group. Migration occurred in one of 33 patients (3%) at 30 days after stent placement.ConclusionThe placement of a 20-mm diameter dual-design stent appears to be clinically safe and effective for the management of colorectal obstruction, with low perforation and migration rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.